Sampling & Analysis

Vinyltrimethoxysilane / CAS# 2768-02-7

NOTE: All prices include media and free pump loan, unless otherwise noted, and excluding passive sampling badges. See Media Fee Schedule.
NEW: Group pricing available for compatible metals and VOCs. Click Here for more information.

Vinyltrimethoxysilane FEE PER SAMPLE: $101.00 COMPATIBLE ANALYTES: METHOD: In-house: GC-SOP-8,-12,-16; GC/FID
Media is special ordered from the vendor.
ANALYTICAL TECHNIQUE:GC/FID COLLECTION MEDIUM:Amberlite XAD-2 ORDER NUMBER:ORBO 609 VOL. / TIME / AREA / MASS:15 L SAMPLING RATE:0.1 LPM LOQ:10 ug

Vinyltrimethoxysilane
Sampling & Analysis

Vinyltrimethoxysilane comes in the form of a colorless liquid.  It is used in combination with other compounds to strengthen fiberglass and resins. 

The substance enters the body through inhalation, ingestion, skin absorption, or skin/eye contact.   It can cause serious irritation of the eyes, skin, and respiratory tract, as well as abdominal distress.

 

View Notes

Notes

  1. Each additional compatible metal $26.
  2. Each additional compatible GC compound $37.
  3. Each additional compatible acid $37.
  4. Each additional compatible HPLC compound $54.
  5. Each additional compatible metals by ICP-MS $33.
  6. Other additional compatible analyte pricing; see additional compatible analyte column.

– Bulks used as analytical standards for GC analysis will be billed at $84
– LOQs listed do not include the desorption efficiency, which could result in higher detection levels. Please call the lab for more information.
– For additional Method information, please refer to the links on Method types.
– Review the published method when determining the correct number of field blanks to submit with your samples.
– The media shelf lives cited are the maximum possible shelf lives. Media should always be used by the expiration date on the label.
– The following surcharges will be added to the listed fees based on the following sample turnaround times:

** Same Day 200%
** Next Day (12pm) 150%
** Next Day (6pm) 100%
** Second Day 75%
** Third Day 50%
** Fourth Day 35%

Symbols Key

Symbols Key

:
Preferred method.
:
Ship overnight refrigerated.
:
Call in advance of sampling to order media.
:
A three sample minimum submittal is required.
:
Collect using 2 tubes in a series.
:
3M recommended maximum sampling hours.
:
Subcontracted analysis.
:
Protect samples from light.
:
Immediately after sampling remove from cassette and place in glass vial.
:
Please send, under separate cover, a sample (bulk) of your particular solvent for use as a reference standard. The bulk sample will be charged the analysis price. Additional analyses and fees may be required to determine the DE for results that do not match a common standard.
:
Reported results reflect elemental analysis of the requested metals. Certain compounds may not be solubilized during digestion, resulting in data that may be biased low.
:
Analyte is referenced in the published method. If more than one published method is cited, the analyte is referenced in at least one of the methods.

Compatibility Codes

A:
Charcoal and carbon disulfide desorption.
B:
Treated XAD-2 (2-(hydroxymethyl) piperidine and toluene desorption.
C:
Silica gel and 95% ethanol desorption.
D:
Tenax and carbon tetrachloride desorption.
E:
OVS Sampler and toluene desorption.
F:
Charcoal and 5% methanol in methylene chloride.
G:
Treated GFF (1-(2 pyridyl) piperazine) and acetonitrile/dimethyl sulfoxide desorption.
U:
Universal Solvent GC Method.

YOUR LOCAL, GLOBAL LAB