Sampling & Analysis

Total Hydrocarbons / CAS# NA

NOTE: All prices include media and free pump loan, unless otherwise noted.

Total Hydrocarbons [2] FEE PER SAMPLE: $65.00 Additional Analyte Fee: $29.00 METHOD: mod. NIOSH 1500/1501; GC/FID
For results above the LOQ, tentative identifications will be provided based on the following list of compounds: acetone, benzene, ethyl alcohol, ethylbenzene, isopropyl alcohol, n-hexane, methyl n-amyl ketone, methylene chloride, methyl ethyl ketone, methyl isobutyl ketone, tetrachloroethylene, toluene, 1,1,1-trichloroethane, trichloroethylene, total trimethylbenzenes, and total xylenes.
ANALYTICAL TECHNIQUE:GC/FID COLLECTION MEDIUM:Charcoal ORDER NUMBER:226-01 VOL. / TIME / AREA / MASS:4 L SAMPLING RATE:0.01-0.2 LPM LOQ:40 ug
Total Hydrocarbons [2] FEE PER SAMPLE: $65.00 Additional Analyte Fee: $29.00 METHOD: mod. NIOSH 1500/1501; GC/FID BADGE
For results above the LOQ, tentative identifications will be provided based on the following list of compounds: acetone, benzene, ethyl alcohol, ethyl benzene, isopropyl alcohol, n-hexane, methyl n-amyl ketone, methylene chloride, methyl ethyl ketone, methyl isobutyl ketone, tetrachloroethylene, toluene, 1,1,1-trichloroethane, trichloroethylene, total trimethylbenzenes, and total xylenes. Interferences: high humidity. The fee for each 3M 3500 badge is US$14 (3M 3520 is US$18) in addition to the analysis fee.
ANALYTICAL TECHNIQUE:GC/FID COLLECTION MEDIUM:PM ORDER NUMBER:3M 3500/ 3M 3520 VOL. / TIME / AREA / MASS:8 hrs. SAMPLING RATE: -- LOQ:40 ug
Total Hydrocarbons [2] FEE PER SAMPLE: $65.00 Additional Analyte Fee: $29.00 METHOD: mod. NIOSH 1500/1501; GC/FID BADGE
For best sampling results, include the charcoal scavenger packet with your returned sampling media. For results above the LOQ, tentative identifications will be provided based on the following list of compounds: acetone, benzene, ethyl alcohol, ethyl benzene, isopropyl alcohol, n-hexane, methyl n-amyl ketone, methylene chloride, methyl ethyl ketone, methyl isobutyl ketone, tetrachloroethylene, toluene, 1,1,1-trichloroethane, trichloroethylene, total trimethylbenzenes, and total xylenes. Interferences: high humidity Manufacturer recommends returning samples to the laboratory within 14 days of the sampling event.
ANALYTICAL TECHNIQUE:GC/FID COLLECTION MEDIUM:PM ORDER NUMBER:N546/ N525/ N566 VOL. / TIME / AREA / MASS:15 min. - 12 hrs. SAMPLING RATE: -- LOQ:40 ug

Total Hydrocarbons
Sampling & Analysis

YOUR LOCAL, GLOBAL LAB