Sampling & Analysis

Inhalable Dust / CAS# NA

NOTE: All prices include media and free pump loan, unless otherwise noted, and excluding passive sampling badges. See Media Fee Schedule.
NEW: Group pricing available for compatible metals and VOCs. Click Here for more information.

Inhalable Dust FEE PER SAMPLE: $31.00 COMPATIBLE ANALYTES: METHOD: mod. NIOSH 0500/MDHS 14/4; GRAV
The recommended air volumes are based on the ACGIH TLV of 10mg/m3. The maximum air volume may be increased if concentrations of airborne dust are below the TLV. The addition of foam plug enables respirable particulate collection on this media in addition to inhalable particulate, but increases the LOQ from 0.10mg to 0.50mg for inhalable particulate. Contact client services for more information.
ANALYTICAL TECHNIQUE:Gravimetric COLLECTION MEDIUM:PVC PW 25mm for DIS ORDER NUMBER:DIS PWPVC VOL. / TIME / AREA / MASS:30-200 L SAMPLING RATE:2 LPM LOQ:0.10 mg
Inhalable Dust FEE PER SAMPLE: $31.00 COMPATIBLE ANALYTES: METHOD: mod. NIOSH 0500/MDHS 14/4; GRAV
The recommended air volumes are based on the ACGIH TLV of 10mg/m3. The maximum air volume may be increased if concentrations of airborne dust are below the TLV. The addition of foam plug enables respirable particulate collection on this media in addition to inhalable particulate, but increases the LOQ from 0.10mg ot 0.50mg for inhalable particulate. Contact client services for more information.
ANALYTICAL TECHNIQUE:Gravimetric COLLECTION MEDIUM:25PVC 5.0 PW ORDER NUMBER:Not Specified VOL. / TIME / AREA / MASS:30-200 L SAMPLING RATE:2 LPM LOQ:0.10 mg
Carbon black (as inhalable dust) FEE PER SAMPLE: $31.00 COMPATIBLE ANALYTES: METHOD: mod. NIOSH 5000; Gravimetric
ANALYTICAL TECHNIQUE:Gravimetric COLLECTION MEDIUM:25PVC 5.0 PW ORDER NUMBER:Not Specified VOL. / TIME / AREA / MASS:33-667 L SAMPLING RATE:2 LPM LOQ:0.10 mg
Flour Dust as Inhalable Dust FEE PER SAMPLE: $31.00 COMPATIBLE ANALYTES: METHOD: mod. NIOSH 0500/MDHS 14/4; GRAV
The recommended air volumes are based on the ACGIH TLV of 0.5mg/m3. The maximum air volume may be increased if concentrations of airborne dust are below the TLV. It is not recommended to combine this analysis with foam inserts for respirable dust due to higher LOQ and longer than 8 hour required sampling time to meet the TLV. Contact client services for more information.
ANALYTICAL TECHNIQUE:Gravimetric COLLECTION MEDIUM:25PVC 5.0 PW ORDER NUMBER:Not Specified VOL. / TIME / AREA / MASS:200 L minimum SAMPLING RATE:2 LPM LOQ:0.10 mg
Flour Dust as Inhalable Dust FEE PER SAMPLE: $31.00 COMPATIBLE ANALYTES: METHOD: mod. NIOSH 0500/MDHS 14/4; GRAV
The recommended air volumes are based on the ACGIH TLV of 0.5mg/m3. The maximum air volume may be increased if concentrations of airborne dust are below the TLV. It is not recommended to combine this analysis with foam inserts for respirable dust due to higher LOQ and longer than 8 hour required sampling time to meet the TLV. Contact client services for more information.
ANALYTICAL TECHNIQUE:Gravimetric COLLECTION MEDIUM:PVC PW 25mm for DIS ORDER NUMBER:DIS PWPVC VOL. / TIME / AREA / MASS:200 L minimum SAMPLING RATE:2 LPM LOQ:0.10 mg

Inhalable Dust
Sampling & Analysis

YOUR LOCAL, GLOBAL LAB