Sampling & Analysis

Cadmium / CAS# 7440-43-9

NOTE: All prices include media and free pump loan, unless otherwise noted, and excluding passive sampling badges. See Media Fee Schedule.
NEW: Group pricing available for compatible metals and VOCs. Click Here for more information.

Cadmium [1] FEE PER SAMPLE: $35.00 COMPATIBLE ANALYTES: $22.00 METHOD: mod. NIOSH 7303; ICP
A minimum air volume of 30 L is required to meet the OSHA PEL by ICP; 300 L is required to meet 1/10th the OSHA PEL by ICP. Lower LOQ available by ICP-MS.
ANALYTICAL TECHNIQUE:ICP/AES COLLECTION MEDIUM:37MCE 0.8 or 25MCE 0.8 ORDER NUMBER:2256SP/ 225-3100 VOL. / TIME / AREA / MASS:300-500,000 L SAMPLING RATE:1-4 LPM LOQ:0.15 ug
Cadmium [5] FEE PER SAMPLE: $41.00 COMPATIBLE ANALYTES: $29.00 METHOD: mod NIOSH 7303; ICP/MS
ANALYTICAL TECHNIQUE:ICP/MS COLLECTION MEDIUM:37MCE 0.8 or 25MCE 0.8 ORDER NUMBER:2256SP/ 225-3100 VOL. / TIME / AREA / MASS:30-500,000 L SAMPLING RATE:1-4 LPM LOQ:0.015 ug
Cadmium [1] FEE PER SAMPLE: $35.00 COMPATIBLE ANALYTES: $22.00 METHOD: mod SW846 3051A/6010C/NIOSH9102 ICP GAMW
ANALYTICAL TECHNIQUE:ICP/AES COLLECTION MEDIUM:Gauze Wipe ORDER NUMBER:3EWE2 VOL. / TIME / AREA / MASS: -- SAMPLING RATE: -- LOQ:0.5 ug
Cadmium [1] FEE PER SAMPLE: $35.00 COMPATIBLE ANALYTES: $22.00 METHOD: mod SW846 3051A/6010C/NIOSH9102 ICP LDMW
ANALYTICAL TECHNIQUE:ICP/AES COLLECTION MEDIUM:Lead Wipe ORDER NUMBER:A22689 VOL. / TIME / AREA / MASS: -- SAMPLING RATE: -- LOQ:0.5 ug
Cadmium [5] FEE PER SAMPLE: $41.00 COMPATIBLE ANALYTES: $29.00 METHOD: mod SW846 3051A/6020A/NIOSH9102 ICPMS LDMW
ANALYTICAL TECHNIQUE:ICP/MS COLLECTION MEDIUM:Lead Wipe ORDER NUMBER:A22689 VOL. / TIME / AREA / MASS: -- SAMPLING RATE: -- LOQ:0.05 ug
Cadmium, Inhalable [1] FEE PER SAMPLE: $44.00 COMPATIBLE ANALYTES: $22.00 METHOD: mod. NIOSH 7303; ICP
A minimum air volume of 30 L is required to meet the OSHA PEL by ICP; 300 L is required to meet 1/10th the OSHA PEL by ICP. Lower LOQ available by ICP-MS.
ANALYTICAL TECHNIQUE:ICP/AES COLLECTION MEDIUM:IOM or DIS ORDER NUMBER:DIS UW PVC VOL. / TIME / AREA / MASS:300-500,000 L SAMPLING RATE:2.0 LPM LOQ:0.15 ug

Cadmium
Sampling & Analysis

Cadmium comes in the form a soft, bluish-white metal.  It is used in the manufacture of batteries, electrical conductors, and metal plating.

The substance enters the body through ingestion (it is found through nature in minute quantities) and inhalation.  It can cause irritation and/or damage to the lungs and kidneys with long-term exposure.

 

YOUR LOCAL, GLOBAL LAB