Sampling & Analysis

Beryllium / CAS# 7440-41-7

NOTE: All prices include media and free pump loan, unless otherwise noted.

Beryllium [1] FEE PER SAMPLE: $33.00 Additional Analyte Fee: $20.00 METHOD: mod. NIOSH 7300/mod. OSHA ID-125G; ICP
If Beryllium Oxide is suspected to be present, sample Beryllium separately and analyze by Beryllium Oxide method mod. NIOSH 7102.
ANALYTICAL TECHNIQUE:ICP/AES COLLECTION MEDIUM:37MCE 0.8 or 25MCE 0.8 ORDER NUMBER:M739MCE/ 225-3100 VOL. / TIME / AREA / MASS:1250-2000 L SAMPLING RATE:1-4 LPM LOQ:0.15 ug
Beryllium [5] FEE PER SAMPLE: $40.00 Additional Analyte Fee: $28.00 METHOD: mod. NIOSH 7300/mod. OSHA ID-125G; ICP/MS
If Beryllium Oxide is suspected to be present, sample Beryllium separately and analyze by Beryllium Oxide method mod. NIOSH 7102.
ANALYTICAL TECHNIQUE:ICP/MS COLLECTION MEDIUM:37MCE 0.8 or 25MCE 0.8 ORDER NUMBER:M739MCE/ 225-3100 VOL. / TIME / AREA / MASS:1250-2000 L SAMPLING RATE:1-4 LPM LOQ:0.0075 ug
Beryllium (Lead Wipe) [1] FEE PER SAMPLE: $40.00 Additional Analyte Fee: $28.00 METHOD: mod. SW846 3051A/3050B/6020A/NIOSH9102 ICPMSLWP
If Beryllium Oxide is suspected to be present, sample Beryllium separately as a vacuum sample on an MCE filter and analyze by Beryllium Oxide method mod. NIOSH 7102.
ANALYTICAL TECHNIQUE:ICP/MS COLLECTION MEDIUM:Lead Wipe ORDER NUMBER:Not Specified VOL. / TIME / AREA / MASS: -- SAMPLING RATE: -- LOQ:0.050 ug
Beryllium (Lead Wipe) [1] FEE PER SAMPLE: $33.00 Additional Analyte Fee: $20.00 METHOD: mod. SW846 3051A/3050B/6010C/NIOSH9102 ICP LDWP
If Beryllium Oxide is suspected to be present, sample Beryllium separately as a vacuum sample on an MCE filter and analyze by Beryllium Oxide method mod. NIOSH 7102.
ANALYTICAL TECHNIQUE:ICP/AES COLLECTION MEDIUM:Lead Wipe ORDER NUMBER: -- VOL. / TIME / AREA / MASS: -- SAMPLING RATE: -- LOQ:0.5 ug
Beryllium (Gauze Wipe) [1] FEE PER SAMPLE: $33.00 Additional Analyte Fee: $20.00 METHOD: mod. NIOSH 9102/SW846 6010C; ICP GAUZE WIPE
If Beryllium Oxide is suspected to be present, sample Beryllium separately as a vacuum sample on an MCE filter and analyze by Beryllium Oxide method mod. NIOSH 7102.
ANALYTICAL TECHNIQUE:ICP/AES COLLECTION MEDIUM:Gauze Wipe ORDER NUMBER: -- VOL. / TIME / AREA / MASS: -- SAMPLING RATE: -- LOQ:0.5 ug
Beryllium (Gauze Wipe) [5] FEE PER SAMPLE: $40.00 Additional Analyte Fee: $28.00 METHOD: mod. NIOSH 9102/SW846 6020/A;ICPMS;GAUZEWP
If Beryllium Oxide is suspected to be present, sample Beryllium separately as a vacuum sample on an MCE filter and analyze by Beryllium Oxide method mod. NIOSH 7102.
ANALYTICAL TECHNIQUE:ICP/MS COLLECTION MEDIUM:Gauze Wipe ORDER NUMBER: -- VOL. / TIME / AREA / MASS: -- SAMPLING RATE: -- LOQ:0.1 ug

Beryllium
Sampling & Analysis

Beryllium comes in the form a gray or white powder.  It is used as an alloying agent in producing beryllium copper, which is extensively used for springs, electrical contacts, spot-welding electrodes, and non-sparking tools. It is applied as a structural material for high-speed aircraft, missiles, spacecraft, and communication satellites. Other uses include windshield frame, brake discs, support beams, and other structural components of the space shuttle.

The substance enters the body through ingestion or inhalation.  It is irritating to the eyes, the skin and the respiratory tract. Inhalation of the dust may cause chemical pneumonitis. Repeated or prolonged contact may cause skin sensitization. Lungs may be affected by repeated or prolonged exposure, resulting in cough, weight loss, and/or weakness. The effects may be delayed, and medical observation is indicated. 

 

YOUR LOCAL, GLOBAL LAB